SCSIQuery 1.34 (15.12.2018) © THOR Generic sense data : Good. Device inquiry data : Device status : connected. Device class : direct access device. Fixed medium device. Device type modifier : 00. ISO version : 00. ECMA version : 00. ANSI version : unknown ANSI version 3. Response data format : SCSI-2. Additional data length 3B. Flags: Relative addressing not supported. 32 bit wide SCSI not supported. 16 bit wide SCSI supported. Synchron data transfer supported. Linked commands not supported. Tagged queues not supported. Device reacts with hard reset. Vendor : ATA Product : TOSHIBA THNSNU02 Version : TA7A Date : 82SS10AG Comment : T65Y Extended inquiry data : 0C 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 00 00 00 00 00 ........ 00 00 00 ... Control page information: Mode Data Length : 191 Medium Type : 0 Device specific : 0 Block des. len : 8 Density code : 0x2 Number of Blocks : 13350832 Block Length : 512 Page code : 0x01 (Page cannot be saved) Page length : 10 Read write error recovery page: *Automatic write reallocation enabled. Automatic read realloaction disabled. *Return defective block to initiator. Tolerate delays to correct erraneous data. Use safest data correction first. *Report recovered errors. Don't terminate data phase upon detection of recovered errors. Do not use error correction codes. Read retry count : 1 Data correction span : 0 bits Head offset count : 0 Strobe offset count : 0 Write retry count : 1 Recovery time limit : 0 ms Page code : 0x02 (Page cannot be saved) Page length : 14 Disconnect reconnect page: Buffer full ratio : 75 % Buffer empty ratio : 25 % Bus inactivity limit : 0 µs Disconnect time limit : 0 µs Connect time limit : 0 µs Maximum burst size : 0 bytes Disconnect control is not used. Page code : 0x03 (Page cannot be saved) Page length : 22 Device format page: Tracks per zone : 1 Spare zone sectors per zone : 32 Spare tracks per zone : 0 Spare tracks per LUN : 0 Sectors per tracks : 63 Bytes per sector : 512 Interleave : 1 Track skew factor : 28 Cylinder skew factor : 28 Soft sector formatting not supported. *Hard sector formatting supported. Removable media not supported. Allocate tracks from the same cylinder first. Page code : 0x04 (Page cannot be saved) Page length : 22 Rigid disk parameter page: Number of cylinders : 8724 Number of heads : 64 Start precompensation at cyl. : 0 Start reduced write at cyl. : 0 Step rate : 51200 ns Landing zone : 256 Spindle synchronization unsupported. Rotational offset : 0 Rotation rate : 7200 rpm Page code : 0x05 (Page cannot be saved) Page length : 30 Flex disk page: Transfer rate : 0 kbit/sec Number of heads : 64 Sectors per cylinder : 63 Bytes per sector : 512 Cylinders : 8724 Start write precomp at cyl. : 0 Start reduced write current : 0 Head step rate : 51200 µs Step pulse width : 0 ms Head settle delay : 0 µs Motor on delay : 0 ms Motor off delay : 0 ms No medium ready signal available. Sectors are numbered starting with 0. Motor ON pin is motor control. Steps for track change : 1 Write precompensation : 0 Head loading time : 0 ms Head unloading time : 0 ms Pin 34 is active low. Pin 34 is open. Pin 2 is active low. Pin 4 is active low. Pin 4 is open. Pin 1 is active low. Pin 1 is open. Rotation rate : 7200 rpm Page code : 0x07 (Page cannot be saved) Page length : 10 Verify error recovery page: Tolerate delays to correct erraneous data. Use safest data correction first. Do not report recovered errors. Don't terminate data phase upon detection of recovered errors. Do not use error correction codes. Verify retry count : 1 Verify correction count : 0 bits Verify recovery time limit : 0 ms Page code : 0x08 (Page cannot be saved) Page length : 10 Cache control page: *Return GOOD after receiving but before writing data to disk. Prefetch data is absolute. READ cache utilized. Demand READ priority : Cache and medium have the same priority. Demand WRITE priority : Cache and medium have the same priority. Prefetch disable treshhold : 0 blocks Minimum prefetch : 0 blocks/factor Maximum prefetch : 0 blocks/factor Maximum prefetch ceiling : 0 blocks Page code : 0x0A (Page cannot be saved) Page length : 6 Device control page: Do not report log exceptions. Queue algorithm : Restricted reordering. Resume queued I/O processes on error. Allow tagged queuing. Extended contingent allegiance disabled. Ready AEN permission disabled. Unit attention AEN permission disabled. Error AEN permission disabled. Ready AEN holdoff period : 0 ms Page code : 0x0C (Page cannot be saved) Page length : 22 Notch page: Device is not notched. Notch boundaries based on physical blocks. Maximum number of notches : 0 Active notch : 0 Starting boundary : cylinder 0 head 0 Ending boundary : cylinder 0 head 0 Notch depended pages mask : 0x0000000000000000 Page code : 0x1C (Page cannot be saved) Page length : 10 Printing RAW page data: 00 04 00 00 00 00 00 00 ........ 00 00 .. Page code : 0x00 (Page cannot be saved) Page length : 2 Operating Parameters Page: Write verify enabled. *Reset status report disabled. Drive operates as removable cartridge drive. Sufficient spare sectors available. Software write protect disabled. Audible eject notification disabled. Write verify enabled, bit 0. Device type qualifier : 00 Device capacity : Capacity in blocks : 46905264. Block length : 512. Blocks from start up to a substiantial delay : Read capacity returned error : Check Condition : Details as below. LBA not valid. Error code of last command. Segment ID : 00. SenseFlags : Sense Key : Illegal request. Additional sense length : 8. Cmd information bytes : 00 00 00 00. Drive specific flags : Extended sense code ASC : 0x24. Extended sense code ASCQ: 0x00. ASC,ASCQ encoded error is invalid field in cdb. Field replaceable unit code FRUC 0x00. Additional flags : Error data output. Byte error. Bit position 0x00. Primary defect list: Read Defect List Header returned error : Check Condition : Details as below. LBA not valid. Error code of last command. Segment ID : 00. SenseFlags : Sense Key : Illegal request. Additional sense length : 8. Cmd information bytes : 00 00 00 00. Drive specific flags : Extended sense code ASC : 0x20. Extended sense code ASCQ: 0x00. ASC,ASCQ encoded error is invalid command operation code. Field replaceable unit code FRUC 0x00. Additional flags : Error data output. Byte error. Bit position 0x00. Grown defect list: Read Defect List Header returned error : Check Condition : Details as below. LBA not valid. Error code of last command. Segment ID : 00. SenseFlags : Sense Key : Illegal request. Additional sense length : 8. Cmd information bytes : 00 00 00 00. Drive specific flags : Extended sense code ASC : 0x20. Extended sense code ASCQ: 0x00. ASC,ASCQ encoded error is invalid command operation code. Field replaceable unit code FRUC 0x00. Additional flags : Error data output. Byte error. Bit position 0x00.