patrik@studio ~ % vim /Volumes/patrik/public_html/SCSIQuery/TransferPeriodFactor-Blizzard1230_SCSI_IV-Seagate_Cheetah_15K.5_ST373455LC-1.txt patrik@studio ~ % for PERIODFACTOR in -1 0 {125..25}; do if [[ $PERIODFACTOR -eq -1 ]]; then echo "------- SYNCHRONOUS AUTONEGOTIATED --------" elif [[ $PERIODFACTOR -eq 0 ]]; then echo "------- ASYNCHRONOUS --------" rsh a1200 PT:MyUnitControl2 UNIT=1 DEVICE=1230scsi.device OFFSET=0 PERIODFACTOR=0 else echo "------- SYNCHRONOUS PERIODFACTOR=$PERIODFACTOR: $((1000000000/(${PERIODFACTOR}*4))) bytes/sec --------" rsh a1200 PT:MyUnitControl2 UNIT=1 DEVICE=1230scsi.device PERIODFACTOR=$PERIODFACTOR fi rsh a1200 "PT:SCSINegotiatedSpeed 1230scsi.device 1;PT:SCSIReadWritespeed 1230scsi.device 1" done ------- SYNCHRONOUS AUTONEGOTIATED -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.06MB/s period factor 31 offset 8 Target: FUJITSU MAT3073NC 5207 Read: 7286075 bytes/sec Write: 6930902 bytes/sec ------- ASYNCHRONOUS -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040514 bytes/sec Write: 2592911 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=125: 2000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039792 bytes/sec Write: 2594037 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=124: 2016129 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040055 bytes/sec Write: 2593019 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=123: 2032520 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041464 bytes/sec Write: 2592833 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=122: 2049180 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041413 bytes/sec Write: 2592754 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=121: 2066115 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040948 bytes/sec Write: 2592993 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=120: 2083333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041521 bytes/sec Write: 2592900 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=119: 2100840 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041957 bytes/sec Write: 2593103 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=118: 2118644 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040338 bytes/sec Write: 2593035 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=117: 2136752 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039969 bytes/sec Write: 2592857 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=116: 2155172 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042028 bytes/sec Write: 2592913 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=115: 2173913 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041824 bytes/sec Write: 2593062 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=114: 2192982 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040579 bytes/sec Write: 2592896 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=113: 2212389 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040234 bytes/sec Write: 2592918 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=112: 2232142 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039294 bytes/sec Write: 2592800 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=111: 2252252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040228 bytes/sec Write: 2593447 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=110: 2272727 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039508 bytes/sec Write: 2592746 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=109: 2293577 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039538 bytes/sec Write: 2592901 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=108: 2314814 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040950 bytes/sec Write: 2592896 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=107: 2336448 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040222 bytes/sec Write: 2593030 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=106: 2358490 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040314 bytes/sec Write: 2593044 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=105: 2380952 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041422 bytes/sec Write: 2592956 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=104: 2403846 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041223 bytes/sec Write: 2593125 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=103: 2427184 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040451 bytes/sec Write: 2593316 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=102: 2450980 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040339 bytes/sec Write: 2592866 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=101: 2475247 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039290 bytes/sec Write: 2592894 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=100: 2500000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041158 bytes/sec Write: 2592941 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=99: 2525252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040817 bytes/sec Write: 2593073 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=98: 2551020 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039730 bytes/sec Write: 2592925 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=97: 2577319 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039630 bytes/sec Write: 2590596 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=96: 2604166 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041598 bytes/sec Write: 2593086 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=95: 2631578 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041573 bytes/sec Write: 2592985 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=94: 2659574 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039971 bytes/sec Write: 2592941 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=93: 2688172 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040696 bytes/sec Write: 2593135 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=92: 2717391 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041824 bytes/sec Write: 2593095 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=91: 2747252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039867 bytes/sec Write: 2593164 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=90: 2777777 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039254 bytes/sec Write: 2593038 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=89: 2808988 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039429 bytes/sec Write: 2592947 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=88: 2840909 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041618 bytes/sec Write: 2592916 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=87: 2873563 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041011 bytes/sec Write: 2592970 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=86: 2906976 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041165 bytes/sec Write: 2593026 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=85: 2941176 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039738 bytes/sec Write: 2592985 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=84: 2976190 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039874 bytes/sec Write: 2593037 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=83: 3012048 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039930 bytes/sec Write: 2592940 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=82: 3048780 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039825 bytes/sec Write: 2592793 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=81: 3086419 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039848 bytes/sec Write: 2593073 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=80: 3125000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041648 bytes/sec Write: 2592960 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=79: 3164556 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039881 bytes/sec Write: 2593081 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=78: 3205128 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041464 bytes/sec Write: 2593174 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=77: 3246753 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039568 bytes/sec Write: 2593003 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=76: 3289473 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040976 bytes/sec Write: 2592936 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=75: 3333333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040506 bytes/sec Write: 2592969 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=74: 3378378 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041656 bytes/sec Write: 2592972 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=73: 3424657 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039991 bytes/sec Write: 2592919 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=72: 3472222 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041686 bytes/sec Write: 2593025 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=71: 3521126 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039965 bytes/sec Write: 2593300 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=70: 3571428 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041726 bytes/sec Write: 2593081 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=69: 3623188 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039172 bytes/sec Write: 2593387 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=68: 3676470 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039911 bytes/sec Write: 2593119 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=67: 3731343 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039529 bytes/sec Write: 2593312 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=66: 3787878 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039268 bytes/sec Write: 2589421 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=65: 3846153 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040626 bytes/sec Write: 2592878 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=64: 3906250 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041440 bytes/sec Write: 2593017 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=63: 3968253 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041363 bytes/sec Write: 2593105 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=62: 4032258 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.03MB/s period factor 62 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3603017 bytes/sec Write: 3327979 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=61: 4098360 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.09MB/s period factor 61 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3603593 bytes/sec Write: 3331279 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=60: 4166666 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.16MB/s period factor 60 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3601742 bytes/sec Write: 3328589 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=59: 4237288 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.23MB/s period factor 59 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3606988 bytes/sec Write: 3328188 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=58: 4310344 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.31MB/s period factor 58 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3607003 bytes/sec Write: 3327974 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=57: 4385964 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.38MB/s period factor 57 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3605196 bytes/sec Write: 3328310 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=56: 4464285 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.46MB/s period factor 56 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3962240 bytes/sec Write: 3616797 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=55: 4545454 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.54MB/s period factor 55 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3962320 bytes/sec Write: 3617292 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=54: 4629629 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.62MB/s period factor 54 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3963886 bytes/sec Write: 3616890 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=53: 4716981 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.71MB/s period factor 53 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3959899 bytes/sec Write: 3617059 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=52: 4807692 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.80MB/s period factor 52 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3964518 bytes/sec Write: 3617212 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=51: 4901960 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.90MB/s period factor 51 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3962049 bytes/sec Write: 3617056 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=50: 5000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 5.00MB/s period factor 50 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4402770 bytes/sec Write: 4146552 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=49: 5102040 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.10MB/s period factor 49 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4944959 bytes/sec Write: 4614728 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=48: 5208333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.20MB/s period factor 48 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4944174 bytes/sec Write: 4615143 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=47: 5319148 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.31MB/s period factor 47 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4950324 bytes/sec Write: 4614694 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=46: 5434782 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.43MB/s period factor 46 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4947016 bytes/sec Write: 4614877 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=45: 5555555 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.55MB/s period factor 45 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4944899 bytes/sec Write: 4614836 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=44: 5681818 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.68MB/s period factor 44 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4948206 bytes/sec Write: 4616045 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=43: 5813953 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.81MB/s period factor 43 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5650678 bytes/sec Write: 5188680 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=42: 5952380 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.95MB/s period factor 42 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5649885 bytes/sec Write: 5188083 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=41: 6097560 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.09MB/s period factor 41 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5650611 bytes/sec Write: 5187914 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=40: 6250000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.25MB/s period factor 40 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5647006 bytes/sec Write: 5187965 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=39: 6410256 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.41MB/s period factor 39 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5649846 bytes/sec Write: 5188524 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=38: 6578947 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.57MB/s period factor 38 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5645504 bytes/sec Write: 5188399 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=37: 6756756 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.75MB/s period factor 37 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6581742 bytes/sec Write: 5939971 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=36: 6944444 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.94MB/s period factor 36 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6573662 bytes/sec Write: 5940507 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=35: 7142857 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.14MB/s period factor 35 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6576849 bytes/sec Write: 5940492 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=34: 7352941 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.35MB/s period factor 34 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6577684 bytes/sec Write: 5941078 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=33: 7575757 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.57MB/s period factor 33 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6577996 bytes/sec Write: 5940488 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=32: 7812500 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.81MB/s period factor 32 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6575857 bytes/sec Write: 5941082 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=31: 8064516 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.06MB/s period factor 31 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7872561 bytes/sec Write: 6931721 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=30: 8333333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.33MB/s period factor 30 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7869579 bytes/sec Write: 6931967 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=29: 8620689 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.62MB/s period factor 29 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7875903 bytes/sec Write: 6930466 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=28: 8928571 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.92MB/s period factor 28 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7873320 bytes/sec Write: 6931521 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=27: 9259259 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 9.25MB/s period factor 27 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7871064 bytes/sec Write: 6931714 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=26: 9615384 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 9.61MB/s period factor 26 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7877722 bytes/sec Write: 6932501 bytes/sec ------- SYNCHRONOUS PERIODFACTOR=25: 10000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 10.00MB/s period factor 25 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 9818507 bytes/sec Write: 9214024 bytes/sec