patrik@studio ~ % for PERIODFACTOR in -1 0 {125..25}; do if [[ $PERIODFACTOR -eq -1 ]]; then echo "------- SYNCHRONOUS AUTONEGOTIATED --------" elif [[ $PERIODFACTOR -eq 0 ]]; then echo "------- ASYNCHRONOUS --------" rsh a1200 PT:MyUnitControl2 UNIT=1 DEVICE=1230scsi.device OFFSET=0 PERIODFACTOR=0 else echo "------- SYNCHRONOUS PERIODFACTOR=$PERIODFACTOR: $((1000000000/(${PERIODFACTOR}*4))) bytes/sec --------" rsh a1200 PT:MyUnitControl2 UNIT=1 DEVICE=1230scsi.device PERIODFACTOR=$PERIODFACTOR fi rsh a1200 "PT:SCSINegotiatedSpeed 1230scsi.device 1;PT:SCSIReadWritespeed 1230scsi.device 1;PT:SCSIOperationSpeed 1230scsi.device 1 ALSO6" done ------- SYNCHRONOUS AUTONEGOTIATED -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.06MB/s period factor 31 offset 8 Target: FUJITSU MAT3073NC 5207 Read: 7255113 bytes/sec Write: 7339292 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.55 ops/sec Seek: 2086.91 ops/sec Read6: 1712.01 ops/sec Read: 1703.64 ops/sec Write6: 1579.17 ops/sec Write: 1569.73 ops/sec ------- ASYNCHRONOUS -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039569 bytes/sec Write: 2744311 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2092.44 ops/sec Seek: 2087.11 ops/sec Read6: 1316.56 ops/sec Read: 1314.70 ops/sec Write6: 1331.04 ops/sec Write: 1325.89 ops/sec ------- SYNCHRONOUS PERIODFACTOR=125: 2000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039503 bytes/sec Write: 2744427 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.73 ops/sec Seek: 2086.70 ops/sec Read6: 1316.03 ops/sec Read: 1307.47 ops/sec Write6: 1336.76 ops/sec Write: 1331.17 ops/sec ------- SYNCHRONOUS PERIODFACTOR=124: 2016129 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041770 bytes/sec Write: 2744434 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.46 ops/sec Seek: 2091.42 ops/sec Read6: 1310.48 ops/sec Read: 1302.96 ops/sec Write6: 1329.91 ops/sec Write: 1324.21 ops/sec ------- SYNCHRONOUS PERIODFACTOR=123: 2032520 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039444 bytes/sec Write: 2744397 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.06 ops/sec Seek: 2086.97 ops/sec Read6: 1316.80 ops/sec Read: 1307.77 ops/sec Write6: 1333.64 ops/sec Write: 1328.06 ops/sec ------- SYNCHRONOUS PERIODFACTOR=122: 2049180 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040493 bytes/sec Write: 2744451 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.97 ops/sec Seek: 2087.23 ops/sec Read6: 1315.94 ops/sec Read: 1309.43 ops/sec Write6: 1328.94 ops/sec Write: 1327.82 ops/sec ------- SYNCHRONOUS PERIODFACTOR=121: 2066115 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040948 bytes/sec Write: 2744455 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.88 ops/sec Seek: 2085.17 ops/sec Read6: 1320.37 ops/sec Read: 1311.90 ops/sec Write6: 1333.91 ops/sec Write: 1325.39 ops/sec ------- SYNCHRONOUS PERIODFACTOR=120: 2083333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040460 bytes/sec Write: 2744460 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.16 ops/sec Seek: 2088.90 ops/sec Read6: 1312.23 ops/sec Read: 1310.69 ops/sec Write6: 1328.75 ops/sec Write: 1325.11 ops/sec ------- SYNCHRONOUS PERIODFACTOR=119: 2100840 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040698 bytes/sec Write: 2744482 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.51 ops/sec Seek: 2082.10 ops/sec Read6: 1318.32 ops/sec Read: 1313.01 ops/sec Write6: 1330.98 ops/sec Write: 1326.77 ops/sec ------- SYNCHRONOUS PERIODFACTOR=118: 2118644 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041529 bytes/sec Write: 2744479 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2092.51 ops/sec Seek: 2091.36 ops/sec Read6: 1311.81 ops/sec Read: 1308.58 ops/sec Write6: 1333.95 ops/sec Write: 1329.03 ops/sec ------- SYNCHRONOUS PERIODFACTOR=117: 2136752 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039204 bytes/sec Write: 2744466 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.70 ops/sec Seek: 2087.93 ops/sec Read6: 1314.44 ops/sec Read: 1305.59 ops/sec Write6: 1330.08 ops/sec Write: 1326.70 ops/sec ------- SYNCHRONOUS PERIODFACTOR=116: 2155172 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041917 bytes/sec Write: 2744102 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.16 ops/sec Seek: 2086.10 ops/sec Read6: 1312.04 ops/sec Read: 1304.21 ops/sec Write6: 1336.34 ops/sec Write: 1333.04 ops/sec ------- SYNCHRONOUS PERIODFACTOR=115: 2173913 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041768 bytes/sec Write: 2744492 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.26 ops/sec Seek: 2085.29 ops/sec Read6: 1313.02 ops/sec Read: 1305.47 ops/sec Write6: 1330.11 ops/sec Write: 1327.07 ops/sec ------- SYNCHRONOUS PERIODFACTOR=114: 2192982 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040490 bytes/sec Write: 2744490 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.80 ops/sec Seek: 2087.61 ops/sec Read6: 1317.59 ops/sec Read: 1312.29 ops/sec Write6: 1336.16 ops/sec Write: 1328.21 ops/sec ------- SYNCHRONOUS PERIODFACTOR=113: 2212389 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040290 bytes/sec Write: 2744477 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2092.37 ops/sec Seek: 2085.89 ops/sec Read6: 1310.88 ops/sec Read: 1305.19 ops/sec Write6: 1328.23 ops/sec Write: 1326.67 ops/sec ------- SYNCHRONOUS PERIODFACTOR=112: 2232142 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042278 bytes/sec Write: 2744471 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.19 ops/sec Seek: 2087.93 ops/sec Read6: 1316.39 ops/sec Read: 1305.36 ops/sec Write6: 1331.98 ops/sec Write: 1327.04 ops/sec ------- SYNCHRONOUS PERIODFACTOR=111: 2252252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040985 bytes/sec Write: 2744518 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.12 ops/sec Seek: 2088.57 ops/sec Read6: 1316.40 ops/sec Read: 1308.44 ops/sec Write6: 1317.90 ops/sec Write: 1325.20 ops/sec ------- SYNCHRONOUS PERIODFACTOR=110: 2272727 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039873 bytes/sec Write: 2744524 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.95 ops/sec Seek: 2073.59 ops/sec Read6: 1278.93 ops/sec Read: 1193.11 ops/sec Write6: 1298.45 ops/sec Write: 1326.55 ops/sec ------- SYNCHRONOUS PERIODFACTOR=109: 2293577 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040377 bytes/sec Write: 2744521 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.70 ops/sec Seek: 2086.96 ops/sec Read6: 1312.96 ops/sec Read: 1310.91 ops/sec Write6: 1334.11 ops/sec Write: 1330.15 ops/sec ------- SYNCHRONOUS PERIODFACTOR=108: 2314814 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039400 bytes/sec Write: 2744519 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.00 ops/sec Seek: 2086.84 ops/sec Read6: 1313.32 ops/sec Read: 1301.52 ops/sec Write6: 1331.60 ops/sec Write: 1325.53 ops/sec ------- SYNCHRONOUS PERIODFACTOR=107: 2336448 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039732 bytes/sec Write: 2744529 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2092.22 ops/sec Seek: 2088.07 ops/sec Read6: 1313.03 ops/sec Read: 1303.67 ops/sec Write6: 1336.29 ops/sec Write: 1331.04 ops/sec ------- SYNCHRONOUS PERIODFACTOR=106: 2358490 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039927 bytes/sec Write: 2744548 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.79 ops/sec Seek: 2083.57 ops/sec Read6: 1310.14 ops/sec Read: 1303.86 ops/sec Write6: 1330.04 ops/sec Write: 1324.79 ops/sec ------- SYNCHRONOUS PERIODFACTOR=105: 2380952 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042269 bytes/sec Write: 2744447 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.03 ops/sec Seek: 2087.57 ops/sec Read6: 1320.14 ops/sec Read: 1311.57 ops/sec Write6: 1333.97 ops/sec Write: 1323.92 ops/sec ------- SYNCHRONOUS PERIODFACTOR=104: 2403846 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039530 bytes/sec Write: 2744569 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.14 ops/sec Seek: 2084.05 ops/sec Read6: 1292.43 ops/sec Read: 1285.06 ops/sec Write6: 1318.89 ops/sec Write: 1310.58 ops/sec ------- SYNCHRONOUS PERIODFACTOR=103: 2427184 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2032484 bytes/sec Write: 2744571 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2092.19 ops/sec Seek: 2027.17 ops/sec Read6: 1205.79 ops/sec Read: 1240.34 ops/sec Write6: 1334.15 ops/sec Write: 1328.52 ops/sec ------- SYNCHRONOUS PERIODFACTOR=102: 2450980 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039853 bytes/sec Write: 2744578 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.92 ops/sec Seek: 2086.91 ops/sec Read6: 1317.48 ops/sec Read: 1309.97 ops/sec Write6: 1330.23 ops/sec Write: 1325.10 ops/sec ------- SYNCHRONOUS PERIODFACTOR=101: 2475247 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040523 bytes/sec Write: 2744570 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.11 ops/sec Seek: 2088.10 ops/sec Read6: 1312.06 ops/sec Read: 1304.08 ops/sec Write6: 1330.53 ops/sec Write: 1326.43 ops/sec ------- SYNCHRONOUS PERIODFACTOR=100: 2500000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040255 bytes/sec Write: 2744562 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.24 ops/sec Seek: 2087.69 ops/sec Read6: 1312.39 ops/sec Read: 1302.11 ops/sec Write6: 1314.24 ops/sec Write: 1281.69 ops/sec ------- SYNCHRONOUS PERIODFACTOR=99: 2525252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2026897 bytes/sec Write: 2708291 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 1864.08 ops/sec Seek: 2016.23 ops/sec Read6: 1279.17 ops/sec Read: 1260.02 ops/sec Write6: 1293.99 ops/sec Write: 1311.62 ops/sec ------- SYNCHRONOUS PERIODFACTOR=98: 2551020 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041758 bytes/sec Write: 2744447 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.67 ops/sec Seek: 2086.70 ops/sec Read6: 1311.33 ops/sec Read: 1303.48 ops/sec Write6: 1329.99 ops/sec Write: 1331.82 ops/sec ------- SYNCHRONOUS PERIODFACTOR=97: 2577319 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041734 bytes/sec Write: 2744540 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.85 ops/sec Seek: 2045.02 ops/sec Read6: 1313.93 ops/sec Read: 1308.49 ops/sec Write6: 1329.94 ops/sec Write: 1323.59 ops/sec ------- SYNCHRONOUS PERIODFACTOR=96: 2604166 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041655 bytes/sec Write: 2744581 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.42 ops/sec Seek: 2084.58 ops/sec Read6: 1314.77 ops/sec Read: 1309.80 ops/sec Write6: 1334.73 ops/sec Write: 1329.13 ops/sec ------- SYNCHRONOUS PERIODFACTOR=95: 2631578 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040861 bytes/sec Write: 2744552 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2084.96 ops/sec Seek: 2088.29 ops/sec Read6: 1312.76 ops/sec Read: 1307.34 ops/sec Write6: 1330.38 ops/sec Write: 1325.31 ops/sec ------- SYNCHRONOUS PERIODFACTOR=94: 2659574 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042360 bytes/sec Write: 2744586 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.71 ops/sec Seek: 2087.38 ops/sec Read6: 1318.98 ops/sec Read: 1312.63 ops/sec Write6: 1333.01 ops/sec Write: 1327.62 ops/sec ------- SYNCHRONOUS PERIODFACTOR=93: 2688172 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040297 bytes/sec Write: 2744573 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2086.77 ops/sec Seek: 2085.86 ops/sec Read6: 1312.98 ops/sec Read: 1306.15 ops/sec Write6: 1330.57 ops/sec Write: 1322.88 ops/sec ------- SYNCHRONOUS PERIODFACTOR=92: 2717391 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040749 bytes/sec Write: 2744582 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.24 ops/sec Seek: 2088.15 ops/sec Read6: 1314.17 ops/sec Read: 1308.85 ops/sec Write6: 1331.66 ops/sec Write: 1327.58 ops/sec ------- SYNCHRONOUS PERIODFACTOR=91: 2747252 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039651 bytes/sec Write: 2744491 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.01 ops/sec Seek: 2083.74 ops/sec Read6: 1310.97 ops/sec Read: 1306.11 ops/sec Write6: 1334.23 ops/sec Write: 1331.66 ops/sec ------- SYNCHRONOUS PERIODFACTOR=90: 2777777 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041207 bytes/sec Write: 2744585 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.86 ops/sec Seek: 2086.21 ops/sec Read6: 1317.34 ops/sec Read: 1309.22 ops/sec Write6: 1330.12 ops/sec Write: 1327.97 ops/sec ------- SYNCHRONOUS PERIODFACTOR=89: 2808988 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041840 bytes/sec Write: 2744582 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.45 ops/sec Seek: 2086.24 ops/sec Read6: 1313.45 ops/sec Read: 1304.84 ops/sec Write6: 1338.77 ops/sec Write: 1330.47 ops/sec ------- SYNCHRONOUS PERIODFACTOR=88: 2840909 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042194 bytes/sec Write: 2744579 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.98 ops/sec Seek: 2084.65 ops/sec Read6: 1313.03 ops/sec Read: 1311.38 ops/sec Write6: 1329.89 ops/sec Write: 1325.62 ops/sec ------- SYNCHRONOUS PERIODFACTOR=87: 2873563 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039086 bytes/sec Write: 2744579 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.23 ops/sec Seek: 2087.85 ops/sec Read6: 1322.12 ops/sec Read: 1316.05 ops/sec Write6: 1333.93 ops/sec Write: 1328.29 ops/sec ------- SYNCHRONOUS PERIODFACTOR=86: 2906976 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039370 bytes/sec Write: 2744565 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.19 ops/sec Seek: 2088.36 ops/sec Read6: 1311.96 ops/sec Read: 1305.25 ops/sec Write6: 1329.26 ops/sec Write: 1326.98 ops/sec ------- SYNCHRONOUS PERIODFACTOR=85: 2941176 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041146 bytes/sec Write: 2744590 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.88 ops/sec Seek: 2084.17 ops/sec Read6: 1316.94 ops/sec Read: 1309.25 ops/sec Write6: 1332.59 ops/sec Write: 1327.48 ops/sec ------- SYNCHRONOUS PERIODFACTOR=84: 2976190 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041075 bytes/sec Write: 2744589 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.39 ops/sec Seek: 2087.01 ops/sec Read6: 1310.83 ops/sec Read: 1302.95 ops/sec Write6: 1329.43 ops/sec Write: 1328.18 ops/sec ------- SYNCHRONOUS PERIODFACTOR=83: 3012048 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041281 bytes/sec Write: 2744578 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.95 ops/sec Seek: 2086.82 ops/sec Read6: 1312.95 ops/sec Read: 1304.74 ops/sec Write6: 1333.56 ops/sec Write: 1327.83 ops/sec ------- SYNCHRONOUS PERIODFACTOR=82: 3048780 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041116 bytes/sec Write: 2740514 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.01 ops/sec Seek: 2086.99 ops/sec Read6: 1314.08 ops/sec Read: 1310.56 ops/sec Write6: 1334.29 ops/sec Write: 1329.36 ops/sec ------- SYNCHRONOUS PERIODFACTOR=81: 3086419 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041254 bytes/sec Write: 2744592 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.87 ops/sec Seek: 2088.49 ops/sec Read6: 1314.69 ops/sec Read: 1307.04 ops/sec Write6: 1330.99 ops/sec Write: 1326.27 ops/sec ------- SYNCHRONOUS PERIODFACTOR=80: 3125000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041195 bytes/sec Write: 2740440 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.69 ops/sec Seek: 2086.82 ops/sec Read6: 1313.27 ops/sec Read: 1301.75 ops/sec Write6: 1335.64 ops/sec Write: 1331.46 ops/sec ------- SYNCHRONOUS PERIODFACTOR=79: 3164556 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041292 bytes/sec Write: 2744589 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.59 ops/sec Seek: 2090.05 ops/sec Read6: 1313.63 ops/sec Read: 1304.28 ops/sec Write6: 1330.07 ops/sec Write: 1325.74 ops/sec ------- SYNCHRONOUS PERIODFACTOR=78: 3205128 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039554 bytes/sec Write: 2744501 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.96 ops/sec Seek: 2084.33 ops/sec Read6: 1319.79 ops/sec Read: 1312.90 ops/sec Write6: 1333.39 ops/sec Write: 1329.31 ops/sec ------- SYNCHRONOUS PERIODFACTOR=77: 3246753 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041459 bytes/sec Write: 2744577 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.99 ops/sec Seek: 2087.14 ops/sec Read6: 1311.40 ops/sec Read: 1302.25 ops/sec Write6: 1330.19 ops/sec Write: 1327.65 ops/sec ------- SYNCHRONOUS PERIODFACTOR=76: 3289473 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041208 bytes/sec Write: 2744527 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.95 ops/sec Seek: 2087.85 ops/sec Read6: 1314.75 ops/sec Read: 1304.99 ops/sec Write6: 1334.24 ops/sec Write: 1326.80 ops/sec ------- SYNCHRONOUS PERIODFACTOR=75: 3333333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040534 bytes/sec Write: 2744610 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.88 ops/sec Seek: 2084.58 ops/sec Read6: 1317.98 ops/sec Read: 1310.36 ops/sec Write6: 1330.19 ops/sec Write: 1325.54 ops/sec ------- SYNCHRONOUS PERIODFACTOR=74: 3378378 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041109 bytes/sec Write: 2744589 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.37 ops/sec Seek: 2086.71 ops/sec Read6: 1313.64 ops/sec Read: 1304.07 ops/sec Write6: 1331.42 ops/sec Write: 1326.38 ops/sec ------- SYNCHRONOUS PERIODFACTOR=73: 3424657 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041987 bytes/sec Write: 2744619 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.89 ops/sec Seek: 2089.47 ops/sec Read6: 1315.22 ops/sec Read: 1308.95 ops/sec Write6: 1333.26 ops/sec Write: 1329.79 ops/sec ------- SYNCHRONOUS PERIODFACTOR=72: 3472222 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041410 bytes/sec Write: 2744598 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.28 ops/sec Seek: 2087.64 ops/sec Read6: 1313.23 ops/sec Read: 1305.51 ops/sec Write6: 1330.90 ops/sec Write: 1325.79 ops/sec ------- SYNCHRONOUS PERIODFACTOR=71: 3521126 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042296 bytes/sec Write: 2744618 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.31 ops/sec Seek: 2083.41 ops/sec Read6: 1312.33 ops/sec Read: 1306.02 ops/sec Write6: 1336.94 ops/sec Write: 1333.12 ops/sec ------- SYNCHRONOUS PERIODFACTOR=70: 3571428 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040243 bytes/sec Write: 2744614 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.16 ops/sec Seek: 2085.92 ops/sec Read6: 1313.60 ops/sec Read: 1304.80 ops/sec Write6: 1333.02 ops/sec Write: 1324.34 ops/sec ------- SYNCHRONOUS PERIODFACTOR=69: 3623188 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040922 bytes/sec Write: 2744604 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.78 ops/sec Seek: 2086.09 ops/sec Read6: 1317.11 ops/sec Read: 1314.24 ops/sec Write6: 1333.64 ops/sec Write: 1328.49 ops/sec ------- SYNCHRONOUS PERIODFACTOR=68: 3676470 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2042428 bytes/sec Write: 2744617 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.42 ops/sec Seek: 2086.74 ops/sec Read6: 1310.82 ops/sec Read: 1304.83 ops/sec Write6: 1330.43 ops/sec Write: 1325.69 ops/sec ------- SYNCHRONOUS PERIODFACTOR=67: 3731343 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2038822 bytes/sec Write: 2744609 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.93 ops/sec Seek: 2084.93 ops/sec Read6: 1314.15 ops/sec Read: 1305.69 ops/sec Write6: 1331.73 ops/sec Write: 1327.05 ops/sec ------- SYNCHRONOUS PERIODFACTOR=66: 3787878 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2040332 bytes/sec Write: 2744623 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.74 ops/sec Seek: 2088.60 ops/sec Read6: 1310.97 ops/sec Read: 1301.54 ops/sec Write6: 1329.55 ops/sec Write: 1324.98 ops/sec ------- SYNCHRONOUS PERIODFACTOR=65: 3846153 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041835 bytes/sec Write: 2744566 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2095.18 ops/sec Seek: 2083.73 ops/sec Read6: 1312.64 ops/sec Read: 1304.83 ops/sec Write6: 1331.49 ops/sec Write: 1326.15 ops/sec ------- SYNCHRONOUS PERIODFACTOR=64: 3906250 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2041370 bytes/sec Write: 2744600 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.88 ops/sec Seek: 2088.69 ops/sec Read6: 1310.11 ops/sec Read: 1302.22 ops/sec Write6: 1334.38 ops/sec Write: 1331.54 ops/sec ------- SYNCHRONOUS PERIODFACTOR=63: 3968253 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Async Narrow SCSI Target: FUJITSU MAT3073NC 5207 Read: 2039762 bytes/sec Write: 2744595 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.11 ops/sec Seek: 2086.45 ops/sec Read6: 1313.09 ops/sec Read: 1304.77 ops/sec Write6: 1332.35 ops/sec Write: 1326.96 ops/sec ------- SYNCHRONOUS PERIODFACTOR=62: 4032258 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.03MB/s period factor 62 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3605313 bytes/sec Write: 3516365 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.35 ops/sec Seek: 2090.11 ops/sec Read6: 1525.07 ops/sec Read: 1521.33 ops/sec Write6: 1405.37 ops/sec Write: 1398.02 ops/sec ------- SYNCHRONOUS PERIODFACTOR=61: 4098360 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.09MB/s period factor 61 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3603999 bytes/sec Write: 3516336 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.81 ops/sec Seek: 2086.89 ops/sec Read6: 1533.00 ops/sec Read: 1525.04 ops/sec Write6: 1402.38 ops/sec Write: 1397.24 ops/sec ------- SYNCHRONOUS PERIODFACTOR=60: 4166666 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.16MB/s period factor 60 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3605402 bytes/sec Write: 3516390 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2086.46 ops/sec Seek: 2089.53 ops/sec Read6: 1532.00 ops/sec Read: 1523.54 ops/sec Write6: 1402.43 ops/sec Write: 1396.83 ops/sec ------- SYNCHRONOUS PERIODFACTOR=59: 4237288 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.23MB/s period factor 59 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3606588 bytes/sec Write: 3516390 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.63 ops/sec Seek: 2090.27 ops/sec Read6: 1527.54 ops/sec Read: 1519.02 ops/sec Write6: 1404.00 ops/sec Write: 1399.47 ops/sec ------- SYNCHRONOUS PERIODFACTOR=58: 4310344 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.31MB/s period factor 58 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3603870 bytes/sec Write: 3516336 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.85 ops/sec Seek: 2086.03 ops/sec Read6: 1535.18 ops/sec Read: 1528.71 ops/sec Write6: 1406.72 ops/sec Write: 1402.62 ops/sec ------- SYNCHRONOUS PERIODFACTOR=57: 4385964 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.38MB/s period factor 57 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3604792 bytes/sec Write: 3516252 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.76 ops/sec Seek: 2086.51 ops/sec Read6: 1540.52 ops/sec Read: 1536.11 ops/sec Write6: 1408.94 ops/sec Write: 1400.27 ops/sec ------- SYNCHRONOUS PERIODFACTOR=56: 4464285 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.46MB/s period factor 56 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3963610 bytes/sec Write: 3828832 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.19 ops/sec Seek: 2087.89 ops/sec Read6: 1566.81 ops/sec Read: 1553.24 ops/sec Write6: 1438.97 ops/sec Write: 1430.23 ops/sec ------- SYNCHRONOUS PERIODFACTOR=55: 4545454 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.54MB/s period factor 55 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3960121 bytes/sec Write: 3828635 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.60 ops/sec Seek: 2085.93 ops/sec Read6: 1560.59 ops/sec Read: 1558.87 ops/sec Write6: 1436.43 ops/sec Write: 1431.51 ops/sec ------- SYNCHRONOUS PERIODFACTOR=54: 4629629 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.62MB/s period factor 54 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3963612 bytes/sec Write: 3828736 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.41 ops/sec Seek: 2088.11 ops/sec Read6: 1570.93 ops/sec Read: 1555.13 ops/sec Write6: 1436.14 ops/sec Write: 1431.31 ops/sec ------- SYNCHRONOUS PERIODFACTOR=53: 4716981 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.71MB/s period factor 53 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3960615 bytes/sec Write: 3828675 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.38 ops/sec Seek: 2087.80 ops/sec Read6: 1559.16 ops/sec Read: 1547.86 ops/sec Write6: 1434.84 ops/sec Write: 1429.90 ops/sec ------- SYNCHRONOUS PERIODFACTOR=52: 4807692 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.80MB/s period factor 52 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3964872 bytes/sec Write: 3828781 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.81 ops/sec Seek: 2088.50 ops/sec Read6: 1557.32 ops/sec Read: 1550.23 ops/sec Write6: 1433.67 ops/sec Write: 1430.99 ops/sec ------- SYNCHRONOUS PERIODFACTOR=51: 4901960 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 4.90MB/s period factor 51 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 3965027 bytes/sec Write: 3828646 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.58 ops/sec Seek: 2085.61 ops/sec Read6: 1562.10 ops/sec Read: 1555.22 ops/sec Write6: 1433.99 ops/sec Write: 1430.47 ops/sec ------- SYNCHRONOUS PERIODFACTOR=50: 5000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-5 Narrow SCSI 5.00MB/s period factor 50 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4401733 bytes/sec Write: 4391647 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.57 ops/sec Seek: 2085.50 ops/sec Read6: 1594.26 ops/sec Read: 1586.35 ops/sec Write6: 1469.92 ops/sec Write: 1458.30 ops/sec ------- SYNCHRONOUS PERIODFACTOR=49: 5102040 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.10MB/s period factor 49 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4947745 bytes/sec Write: 4881142 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2085.97 ops/sec Seek: 2086.52 ops/sec Read6: 1622.55 ops/sec Read: 1614.60 ops/sec Write6: 1495.30 ops/sec Write: 1487.92 ops/sec ------- SYNCHRONOUS PERIODFACTOR=48: 5208333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.20MB/s period factor 48 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4948086 bytes/sec Write: 4881563 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.07 ops/sec Seek: 2087.14 ops/sec Read6: 1623.79 ops/sec Read: 1613.29 ops/sec Write6: 1492.85 ops/sec Write: 1489.02 ops/sec ------- SYNCHRONOUS PERIODFACTOR=47: 5319148 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.31MB/s period factor 47 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4950690 bytes/sec Write: 4881093 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.70 ops/sec Seek: 2085.36 ops/sec Read6: 1647.48 ops/sec Read: 1637.72 ops/sec Write6: 1498.10 ops/sec Write: 1492.24 ops/sec ------- SYNCHRONOUS PERIODFACTOR=46: 5434782 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.43MB/s period factor 46 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4948923 bytes/sec Write: 4881570 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.62 ops/sec Seek: 2089.92 ops/sec Read6: 1626.97 ops/sec Read: 1621.11 ops/sec Write6: 1493.86 ops/sec Write: 1488.83 ops/sec ------- SYNCHRONOUS PERIODFACTOR=45: 5555555 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.55MB/s period factor 45 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4951033 bytes/sec Write: 4881135 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.72 ops/sec Seek: 2083.28 ops/sec Read6: 1628.62 ops/sec Read: 1619.14 ops/sec Write6: 1495.10 ops/sec Write: 1490.68 ops/sec ------- SYNCHRONOUS PERIODFACTOR=44: 5681818 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.68MB/s period factor 44 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 4946122 bytes/sec Write: 4881073 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.53 ops/sec Seek: 2086.61 ops/sec Read6: 1622.37 ops/sec Read: 1610.45 ops/sec Write6: 1499.79 ops/sec Write: 1494.74 ops/sec ------- SYNCHRONOUS PERIODFACTOR=43: 5813953 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.81MB/s period factor 43 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5648103 bytes/sec Write: 5492973 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.39 ops/sec Seek: 2087.87 ops/sec Read6: 1661.69 ops/sec Read: 1653.49 ops/sec Write6: 1534.63 ops/sec Write: 1523.68 ops/sec ------- SYNCHRONOUS PERIODFACTOR=42: 5952380 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 5.95MB/s period factor 42 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5646055 bytes/sec Write: 5492824 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.97 ops/sec Seek: 2086.20 ops/sec Read6: 1660.18 ops/sec Read: 1651.37 ops/sec Write6: 1529.78 ops/sec Write: 1522.84 ops/sec ------- SYNCHRONOUS PERIODFACTOR=41: 6097560 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.09MB/s period factor 41 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5643537 bytes/sec Write: 5492923 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2090.12 ops/sec Seek: 2084.83 ops/sec Read6: 1665.83 ops/sec Read: 1652.83 ops/sec Write6: 1532.45 ops/sec Write: 1523.01 ops/sec ------- SYNCHRONOUS PERIODFACTOR=40: 6250000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.25MB/s period factor 40 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5645212 bytes/sec Write: 5493037 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2086.97 ops/sec Seek: 2088.12 ops/sec Read6: 1664.12 ops/sec Read: 1653.45 ops/sec Write6: 1534.00 ops/sec Write: 1526.82 ops/sec ------- SYNCHRONOUS PERIODFACTOR=39: 6410256 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.41MB/s period factor 39 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5646507 bytes/sec Write: 5493753 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.26 ops/sec Seek: 2089.95 ops/sec Read6: 1657.97 ops/sec Read: 1649.90 ops/sec Write6: 1533.11 ops/sec Write: 1528.19 ops/sec ------- SYNCHRONOUS PERIODFACTOR=38: 6578947 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.57MB/s period factor 38 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 5647023 bytes/sec Write: 5492730 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.55 ops/sec Seek: 2084.29 ops/sec Read6: 1665.55 ops/sec Read: 1658.62 ops/sec Write6: 1533.81 ops/sec Write: 1528.16 ops/sec ------- SYNCHRONOUS PERIODFACTOR=37: 6756756 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.75MB/s period factor 37 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6580018 bytes/sec Write: 6279697 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.14 ops/sec Seek: 2085.42 ops/sec Read6: 1705.60 ops/sec Read: 1695.82 ops/sec Write6: 1547.07 ops/sec Write: 1548.06 ops/sec ------- SYNCHRONOUS PERIODFACTOR=36: 6944444 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 6.94MB/s period factor 36 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6574180 bytes/sec Write: 6279825 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.42 ops/sec Seek: 2087.87 ops/sec Read6: 1693.89 ops/sec Read: 1681.01 ops/sec Write6: 1549.46 ops/sec Write: 1544.98 ops/sec ------- SYNCHRONOUS PERIODFACTOR=35: 7142857 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.14MB/s period factor 35 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6575096 bytes/sec Write: 6279812 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.07 ops/sec Seek: 2084.15 ops/sec Read6: 1694.69 ops/sec Read: 1686.91 ops/sec Write6: 1548.63 ops/sec Write: 1545.90 ops/sec ------- SYNCHRONOUS PERIODFACTOR=34: 7352941 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.35MB/s period factor 34 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6572797 bytes/sec Write: 6280152 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.29 ops/sec Seek: 2087.29 ops/sec Read6: 1713.36 ops/sec Read: 1702.42 ops/sec Write6: 1550.66 ops/sec Write: 1546.25 ops/sec ------- SYNCHRONOUS PERIODFACTOR=33: 7575757 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.57MB/s period factor 33 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6576967 bytes/sec Write: 6279730 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.46 ops/sec Seek: 2091.89 ops/sec Read6: 1702.35 ops/sec Read: 1690.57 ops/sec Write6: 1548.93 ops/sec Write: 1541.18 ops/sec ------- SYNCHRONOUS PERIODFACTOR=32: 7812500 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 7.81MB/s period factor 32 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 6578639 bytes/sec Write: 6279660 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2093.21 ops/sec Seek: 2085.82 ops/sec Read6: 1695.79 ops/sec Read: 1683.29 ops/sec Write6: 1548.16 ops/sec Write: 1543.83 ops/sec ------- SYNCHRONOUS PERIODFACTOR=31: 8064516 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.06MB/s period factor 31 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7879109 bytes/sec Write: 7339620 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.64 ops/sec Seek: 2087.35 ops/sec Read6: 1740.45 ops/sec Read: 1727.22 ops/sec Write6: 1574.64 ops/sec Write: 1572.41 ops/sec ------- SYNCHRONOUS PERIODFACTOR=30: 8333333 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.33MB/s period factor 30 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7879418 bytes/sec Write: 7328807 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.04 ops/sec Seek: 2087.28 ops/sec Read6: 1741.50 ops/sec Read: 1731.19 ops/sec Write6: 1578.96 ops/sec Write: 1570.48 ops/sec ------- SYNCHRONOUS PERIODFACTOR=29: 8620689 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.62MB/s period factor 29 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7870223 bytes/sec Write: 7339925 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2088.57 ops/sec Seek: 2088.02 ops/sec Read6: 1731.24 ops/sec Read: 1721.28 ops/sec Write6: 1577.77 ops/sec Write: 1571.52 ops/sec ------- SYNCHRONOUS PERIODFACTOR=28: 8928571 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 8.92MB/s period factor 28 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7876464 bytes/sec Write: 7339747 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2089.91 ops/sec Seek: 2085.15 ops/sec Read6: 1739.31 ops/sec Read: 1725.67 ops/sec Write6: 1573.54 ops/sec Write: 1565.34 ops/sec ------- SYNCHRONOUS PERIODFACTOR=27: 9259259 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 9.25MB/s period factor 27 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7873646 bytes/sec Write: 7339726 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2087.99 ops/sec Seek: 2082.74 ops/sec Read6: 1733.57 ops/sec Read: 1717.69 ops/sec Write6: 1576.44 ops/sec Write: 1569.59 ops/sec ------- SYNCHRONOUS PERIODFACTOR=26: 9615384 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 9.61MB/s period factor 26 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 7875160 bytes/sec Write: 7339731 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2091.78 ops/sec Seek: 2088.71 ops/sec Read6: 1747.67 ops/sec Read: 1739.36 ops/sec Write6: 1576.36 ops/sec Write: 1572.81 ops/sec ------- SYNCHRONOUS PERIODFACTOR=25: 10000000 bytes/sec -------- Target: FUJITSU MAT3073NC 5207 Negotiated: Fast-10 Narrow SCSI 10.00MB/s period factor 25 offset 15 Target: FUJITSU MAT3073NC 5207 Read: 9819270 bytes/sec Write: 9761128 bytes/sec Target: FUJITSU MAT3073NC 5207 Seek6: 2094.42 ops/sec Seek: 2083.66 ops/sec Read6: 1779.78 ops/sec Read: 1766.96 ops/sec Write6: 1619.68 ops/sec Write: 1616.27 ops/sec