patrik@studio ~ % for PERIODFACTOR in {256..25}; do echo "------- PERIODFACTOR=$PERIODFACTOR: $((1000000000/(${PERIODFACTOR}*4))) bytes/sec --------" if [[ $PERIODFACTOR -gt 255 ]]; then rsh a1200 pt:myunitcontrol2 UNIT=1 DEVICE=1230scsi.device OFFSET=0 PERIODFACTOR=0 else rsh a1200 pt:myunitcontrol2 UNIT=1 DEVICE=1230scsi.device PERIODFACTOR=$PERIODFACTOR fi rsh a1200 "pt:scsinegotiatedspeed 1230scsi.device 1;pt:scsireadwritespeed 1230scsi.device 1" done ------- PERIODFACTOR=256: 976562 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2408036 bytes/sec Write: 3120764 bytes/sec ------- PERIODFACTOR=255: 980392 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409961 bytes/sec Write: 3123288 bytes/sec ------- PERIODFACTOR=254: 984251 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2408484 bytes/sec Write: 3125588 bytes/sec ------- PERIODFACTOR=253: 988142 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410586 bytes/sec Write: 3126655 bytes/sec ------- PERIODFACTOR=252: 992063 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409822 bytes/sec Write: 3126562 bytes/sec ------- PERIODFACTOR=251: 996015 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409284 bytes/sec Write: 3126662 bytes/sec ------- PERIODFACTOR=250: 1000000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410784 bytes/sec Write: 3123452 bytes/sec ------- PERIODFACTOR=249: 1004016 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410585 bytes/sec Write: 3126792 bytes/sec ------- PERIODFACTOR=248: 1008064 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410397 bytes/sec Write: 3123680 bytes/sec ------- PERIODFACTOR=247: 1012145 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409387 bytes/sec Write: 3123871 bytes/sec ------- PERIODFACTOR=246: 1016260 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409237 bytes/sec Write: 3126942 bytes/sec ------- PERIODFACTOR=245: 1020408 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410917 bytes/sec Write: 3127017 bytes/sec ------- PERIODFACTOR=244: 1024590 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409550 bytes/sec Write: 3126900 bytes/sec ------- PERIODFACTOR=243: 1028806 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409854 bytes/sec Write: 3117548 bytes/sec ------- PERIODFACTOR=242: 1033057 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411123 bytes/sec Write: 3126977 bytes/sec ------- PERIODFACTOR=241: 1037344 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410215 bytes/sec Write: 3127055 bytes/sec ------- PERIODFACTOR=240: 1041666 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2407213 bytes/sec Write: 3124016 bytes/sec ------- PERIODFACTOR=239: 1046025 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409381 bytes/sec Write: 3126860 bytes/sec ------- PERIODFACTOR=238: 1050420 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409333 bytes/sec Write: 3123577 bytes/sec ------- PERIODFACTOR=237: 1054852 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410167 bytes/sec Write: 3127026 bytes/sec ------- PERIODFACTOR=236: 1059322 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410942 bytes/sec Write: 3126549 bytes/sec ------- PERIODFACTOR=235: 1063829 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409489 bytes/sec Write: 3123740 bytes/sec ------- PERIODFACTOR=234: 1068376 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409700 bytes/sec Write: 3126864 bytes/sec ------- PERIODFACTOR=233: 1072961 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410408 bytes/sec Write: 3123908 bytes/sec ------- PERIODFACTOR=232: 1077586 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409507 bytes/sec Write: 3123564 bytes/sec ------- PERIODFACTOR=231: 1082251 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409834 bytes/sec Write: 3123799 bytes/sec ------- PERIODFACTOR=230: 1086956 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410972 bytes/sec Write: 3126831 bytes/sec ------- PERIODFACTOR=229: 1091703 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409284 bytes/sec Write: 3117578 bytes/sec ------- PERIODFACTOR=228: 1096491 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409274 bytes/sec Write: 3123638 bytes/sec ------- PERIODFACTOR=227: 1101321 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409661 bytes/sec Write: 3126851 bytes/sec ------- PERIODFACTOR=226: 1106194 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409348 bytes/sec Write: 3126719 bytes/sec ------- PERIODFACTOR=225: 1111111 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411102 bytes/sec Write: 3126868 bytes/sec ------- PERIODFACTOR=224: 1116071 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410021 bytes/sec Write: 3123593 bytes/sec ------- PERIODFACTOR=223: 1121076 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409551 bytes/sec Write: 3127076 bytes/sec ------- PERIODFACTOR=222: 1126126 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409146 bytes/sec Write: 3123853 bytes/sec ------- PERIODFACTOR=221: 1131221 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409314 bytes/sec Write: 3120550 bytes/sec ------- PERIODFACTOR=220: 1136363 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410945 bytes/sec Write: 3126845 bytes/sec ------- PERIODFACTOR=219: 1141552 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411013 bytes/sec Write: 3123634 bytes/sec ------- PERIODFACTOR=218: 1146788 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409349 bytes/sec Write: 3126983 bytes/sec ------- PERIODFACTOR=217: 1152073 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409321 bytes/sec Write: 3120684 bytes/sec ------- PERIODFACTOR=216: 1157407 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410997 bytes/sec Write: 3126728 bytes/sec ------- PERIODFACTOR=215: 1162790 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411020 bytes/sec Write: 3126556 bytes/sec ------- PERIODFACTOR=214: 1168224 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409449 bytes/sec Write: 3126734 bytes/sec ------- PERIODFACTOR=213: 1173708 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411380 bytes/sec Write: 3123669 bytes/sec ------- PERIODFACTOR=212: 1179245 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409609 bytes/sec Write: 3120530 bytes/sec ------- PERIODFACTOR=211: 1184834 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409535 bytes/sec Write: 3126895 bytes/sec ------- PERIODFACTOR=210: 1190476 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409968 bytes/sec Write: 3125073 bytes/sec ------- PERIODFACTOR=209: 1196172 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2386768 bytes/sec Write: 3122935 bytes/sec ------- PERIODFACTOR=208: 1201923 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409257 bytes/sec Write: 3127059 bytes/sec ------- PERIODFACTOR=207: 1207729 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410345 bytes/sec Write: 3124007 bytes/sec ------- PERIODFACTOR=206: 1213592 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409368 bytes/sec Write: 3123693 bytes/sec ------- PERIODFACTOR=205: 1219512 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409585 bytes/sec Write: 3124190 bytes/sec ------- PERIODFACTOR=204: 1225490 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410015 bytes/sec Write: 3120743 bytes/sec ------- PERIODFACTOR=203: 1231527 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411019 bytes/sec Write: 3123798 bytes/sec ------- PERIODFACTOR=202: 1237623 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410784 bytes/sec Write: 3126714 bytes/sec ------- PERIODFACTOR=201: 1243781 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409878 bytes/sec Write: 3123898 bytes/sec ------- PERIODFACTOR=200: 1250000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409714 bytes/sec Write: 3123908 bytes/sec ------- PERIODFACTOR=199: 1256281 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409763 bytes/sec Write: 3123752 bytes/sec ------- PERIODFACTOR=198: 1262626 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410513 bytes/sec Write: 3123684 bytes/sec ------- PERIODFACTOR=197: 1269035 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409740 bytes/sec Write: 3123622 bytes/sec ------- PERIODFACTOR=196: 1275510 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409150 bytes/sec Write: 3124077 bytes/sec ------- PERIODFACTOR=195: 1282051 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410826 bytes/sec Write: 3126918 bytes/sec ------- PERIODFACTOR=194: 1288659 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410418 bytes/sec Write: 3126719 bytes/sec ------- PERIODFACTOR=193: 1295336 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410236 bytes/sec Write: 3120529 bytes/sec ------- PERIODFACTOR=192: 1302083 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410883 bytes/sec Write: 3126564 bytes/sec ------- PERIODFACTOR=191: 1308900 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411059 bytes/sec Write: 3125162 bytes/sec ------- PERIODFACTOR=190: 1315789 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410689 bytes/sec Write: 3126977 bytes/sec ------- PERIODFACTOR=189: 1322751 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410193 bytes/sec Write: 3126889 bytes/sec ------- PERIODFACTOR=188: 1329787 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410545 bytes/sec Write: 3120703 bytes/sec ------- PERIODFACTOR=187: 1336898 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411350 bytes/sec Write: 3126822 bytes/sec ------- PERIODFACTOR=186: 1344086 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410979 bytes/sec Write: 3126854 bytes/sec ------- PERIODFACTOR=185: 1351351 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411041 bytes/sec Write: 3126724 bytes/sec ------- PERIODFACTOR=184: 1358695 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409911 bytes/sec Write: 3126966 bytes/sec ------- PERIODFACTOR=183: 1366120 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410807 bytes/sec Write: 3126982 bytes/sec ------- PERIODFACTOR=182: 1373626 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411220 bytes/sec Write: 3123828 bytes/sec ------- PERIODFACTOR=181: 1381215 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410459 bytes/sec Write: 3123565 bytes/sec ------- PERIODFACTOR=180: 1388888 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410186 bytes/sec Write: 3126791 bytes/sec ------- PERIODFACTOR=179: 1396648 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409415 bytes/sec Write: 3123479 bytes/sec ------- PERIODFACTOR=178: 1404494 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410764 bytes/sec Write: 3123978 bytes/sec ------- PERIODFACTOR=177: 1412429 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411183 bytes/sec Write: 3124728 bytes/sec ------- PERIODFACTOR=176: 1420454 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409819 bytes/sec Write: 3123746 bytes/sec ------- PERIODFACTOR=175: 1428571 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410837 bytes/sec Write: 3123659 bytes/sec ------- PERIODFACTOR=174: 1436781 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409279 bytes/sec Write: 3123524 bytes/sec ------- PERIODFACTOR=173: 1445086 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410742 bytes/sec Write: 3126762 bytes/sec ------- PERIODFACTOR=172: 1453488 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411291 bytes/sec Write: 3126757 bytes/sec ------- PERIODFACTOR=171: 1461988 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409575 bytes/sec Write: 3123953 bytes/sec ------- PERIODFACTOR=170: 1470588 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409191 bytes/sec Write: 3123660 bytes/sec ------- PERIODFACTOR=169: 1479289 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410877 bytes/sec Write: 3126797 bytes/sec ------- PERIODFACTOR=168: 1488095 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410066 bytes/sec Write: 3126881 bytes/sec ------- PERIODFACTOR=167: 1497005 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409668 bytes/sec Write: 3126923 bytes/sec ------- PERIODFACTOR=166: 1506024 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411348 bytes/sec Write: 3126700 bytes/sec ------- PERIODFACTOR=165: 1515151 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410798 bytes/sec Write: 3123808 bytes/sec ------- PERIODFACTOR=164: 1524390 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409800 bytes/sec Write: 3123596 bytes/sec ------- PERIODFACTOR=163: 1533742 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410874 bytes/sec Write: 3123679 bytes/sec ------- PERIODFACTOR=162: 1543209 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409272 bytes/sec Write: 3126861 bytes/sec ------- PERIODFACTOR=161: 1552795 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410924 bytes/sec Write: 3126686 bytes/sec ------- PERIODFACTOR=160: 1562500 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409358 bytes/sec Write: 3125211 bytes/sec ------- PERIODFACTOR=159: 1572327 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411076 bytes/sec Write: 3126663 bytes/sec ------- PERIODFACTOR=158: 1582278 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409574 bytes/sec Write: 3126766 bytes/sec ------- PERIODFACTOR=157: 1592356 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409359 bytes/sec Write: 3126809 bytes/sec ------- PERIODFACTOR=156: 1602564 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410776 bytes/sec Write: 3126766 bytes/sec ------- PERIODFACTOR=155: 1612903 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410123 bytes/sec Write: 3126746 bytes/sec ------- PERIODFACTOR=154: 1623376 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409499 bytes/sec Write: 3126933 bytes/sec ------- PERIODFACTOR=153: 1633986 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409593 bytes/sec Write: 3126848 bytes/sec ------- PERIODFACTOR=152: 1644736 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410907 bytes/sec Write: 3126707 bytes/sec ------- PERIODFACTOR=151: 1655629 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409261 bytes/sec Write: 3123763 bytes/sec ------- PERIODFACTOR=150: 1666666 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409581 bytes/sec Write: 3126909 bytes/sec ------- PERIODFACTOR=149: 1677852 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409150 bytes/sec Write: 3117776 bytes/sec ------- PERIODFACTOR=148: 1689189 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409975 bytes/sec Write: 3126671 bytes/sec ------- PERIODFACTOR=147: 1700680 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410274 bytes/sec Write: 3123600 bytes/sec ------- PERIODFACTOR=146: 1712328 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410456 bytes/sec Write: 3123645 bytes/sec ------- PERIODFACTOR=145: 1724137 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410630 bytes/sec Write: 3123628 bytes/sec ------- PERIODFACTOR=144: 1736111 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411069 bytes/sec Write: 3126748 bytes/sec ------- PERIODFACTOR=143: 1748251 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411282 bytes/sec Write: 3117302 bytes/sec ------- PERIODFACTOR=142: 1760563 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410012 bytes/sec Write: 3126634 bytes/sec ------- PERIODFACTOR=141: 1773049 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410220 bytes/sec Write: 3123601 bytes/sec ------- PERIODFACTOR=140: 1785714 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411380 bytes/sec Write: 3126927 bytes/sec ------- PERIODFACTOR=139: 1798561 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410608 bytes/sec Write: 3120672 bytes/sec ------- PERIODFACTOR=138: 1811594 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410492 bytes/sec Write: 3126792 bytes/sec ------- PERIODFACTOR=137: 1824817 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410821 bytes/sec Write: 3120510 bytes/sec ------- PERIODFACTOR=136: 1838235 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410707 bytes/sec Write: 3123786 bytes/sec ------- PERIODFACTOR=135: 1851851 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410808 bytes/sec Write: 3123800 bytes/sec ------- PERIODFACTOR=134: 1865671 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410993 bytes/sec Write: 3123834 bytes/sec ------- PERIODFACTOR=133: 1879699 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409461 bytes/sec Write: 3123819 bytes/sec ------- PERIODFACTOR=132: 1893939 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2408841 bytes/sec Write: 3069336 bytes/sec ------- PERIODFACTOR=131: 1908396 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410161 bytes/sec Write: 3124663 bytes/sec ------- PERIODFACTOR=130: 1923076 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410808 bytes/sec Write: 3123524 bytes/sec ------- PERIODFACTOR=129: 1937984 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409740 bytes/sec Write: 3123657 bytes/sec ------- PERIODFACTOR=128: 1953125 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409247 bytes/sec Write: 3126879 bytes/sec ------- PERIODFACTOR=127: 1968503 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411033 bytes/sec Write: 3126768 bytes/sec ------- PERIODFACTOR=126: 1984126 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410414 bytes/sec Write: 3126686 bytes/sec ------- PERIODFACTOR=125: 2000000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410276 bytes/sec Write: 3117757 bytes/sec ------- PERIODFACTOR=124: 2016129 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409611 bytes/sec Write: 3126754 bytes/sec ------- PERIODFACTOR=123: 2032520 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411220 bytes/sec Write: 3126796 bytes/sec ------- PERIODFACTOR=122: 2049180 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2408957 bytes/sec Write: 3120942 bytes/sec ------- PERIODFACTOR=121: 2066115 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410560 bytes/sec Write: 3123782 bytes/sec ------- PERIODFACTOR=120: 2083333 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410308 bytes/sec Write: 3123851 bytes/sec ------- PERIODFACTOR=119: 2100840 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411307 bytes/sec Write: 3123860 bytes/sec ------- PERIODFACTOR=118: 2118644 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410275 bytes/sec Write: 3126631 bytes/sec ------- PERIODFACTOR=117: 2136752 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411080 bytes/sec Write: 3124208 bytes/sec ------- PERIODFACTOR=116: 2155172 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410183 bytes/sec Write: 3126948 bytes/sec ------- PERIODFACTOR=115: 2173913 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409029 bytes/sec Write: 3124103 bytes/sec ------- PERIODFACTOR=114: 2192982 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409536 bytes/sec Write: 3120559 bytes/sec ------- PERIODFACTOR=113: 2212389 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411180 bytes/sec Write: 3123587 bytes/sec ------- PERIODFACTOR=112: 2232142 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409929 bytes/sec Write: 3126724 bytes/sec ------- PERIODFACTOR=111: 2252252 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409959 bytes/sec Write: 3126934 bytes/sec ------- PERIODFACTOR=110: 2272727 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410935 bytes/sec Write: 3126886 bytes/sec ------- PERIODFACTOR=109: 2293577 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410283 bytes/sec Write: 3126844 bytes/sec ------- PERIODFACTOR=108: 2314814 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410308 bytes/sec Write: 3120880 bytes/sec ------- PERIODFACTOR=107: 2336448 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409463 bytes/sec Write: 3123791 bytes/sec ------- PERIODFACTOR=106: 2358490 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410928 bytes/sec Write: 3126863 bytes/sec ------- PERIODFACTOR=105: 2380952 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410641 bytes/sec Write: 3123637 bytes/sec ------- PERIODFACTOR=104: 2403846 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410994 bytes/sec Write: 3126797 bytes/sec ------- PERIODFACTOR=103: 2427184 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409917 bytes/sec Write: 3123769 bytes/sec ------- PERIODFACTOR=102: 2450980 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409486 bytes/sec Write: 3120374 bytes/sec ------- PERIODFACTOR=101: 2475247 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410823 bytes/sec Write: 3126896 bytes/sec ------- PERIODFACTOR=100: 2500000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410215 bytes/sec Write: 3126820 bytes/sec ------- PERIODFACTOR=99: 2525252 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409745 bytes/sec Write: 3123776 bytes/sec ------- PERIODFACTOR=98: 2551020 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411229 bytes/sec Write: 3126971 bytes/sec ------- PERIODFACTOR=97: 2577319 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410004 bytes/sec Write: 3126891 bytes/sec ------- PERIODFACTOR=96: 2604166 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409350 bytes/sec Write: 3126931 bytes/sec ------- PERIODFACTOR=95: 2631578 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410021 bytes/sec Write: 3126963 bytes/sec ------- PERIODFACTOR=94: 2659574 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411469 bytes/sec Write: 3126844 bytes/sec ------- PERIODFACTOR=93: 2688172 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410996 bytes/sec Write: 3126758 bytes/sec ------- PERIODFACTOR=92: 2717391 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409055 bytes/sec Write: 3123961 bytes/sec ------- PERIODFACTOR=91: 2747252 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409438 bytes/sec Write: 3123925 bytes/sec ------- PERIODFACTOR=90: 2777777 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409500 bytes/sec Write: 3124008 bytes/sec ------- PERIODFACTOR=89: 2808988 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409210 bytes/sec Write: 3126877 bytes/sec ------- PERIODFACTOR=88: 2840909 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409574 bytes/sec Write: 3126740 bytes/sec ------- PERIODFACTOR=87: 2873563 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409426 bytes/sec Write: 3126957 bytes/sec ------- PERIODFACTOR=86: 2906976 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409307 bytes/sec Write: 3126956 bytes/sec ------- PERIODFACTOR=85: 2941176 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409112 bytes/sec Write: 3123824 bytes/sec ------- PERIODFACTOR=84: 2976190 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410776 bytes/sec Write: 3126989 bytes/sec ------- PERIODFACTOR=83: 3012048 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410789 bytes/sec Write: 3124137 bytes/sec ------- PERIODFACTOR=82: 3048780 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409970 bytes/sec Write: 3126936 bytes/sec ------- PERIODFACTOR=81: 3086419 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411330 bytes/sec Write: 3120610 bytes/sec ------- PERIODFACTOR=80: 3125000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410862 bytes/sec Write: 3120975 bytes/sec ------- PERIODFACTOR=79: 3164556 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410454 bytes/sec Write: 3123627 bytes/sec ------- PERIODFACTOR=78: 3205128 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409998 bytes/sec Write: 3126883 bytes/sec ------- PERIODFACTOR=77: 3246753 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409050 bytes/sec Write: 3124037 bytes/sec ------- PERIODFACTOR=76: 3289473 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409045 bytes/sec Write: 3123888 bytes/sec ------- PERIODFACTOR=75: 3333333 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410380 bytes/sec Write: 3120795 bytes/sec ------- PERIODFACTOR=74: 3378378 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409777 bytes/sec Write: 3126988 bytes/sec ------- PERIODFACTOR=73: 3424657 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409567 bytes/sec Write: 3123668 bytes/sec ------- PERIODFACTOR=72: 3472222 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409563 bytes/sec Write: 3126851 bytes/sec ------- PERIODFACTOR=71: 3521126 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410993 bytes/sec Write: 3120807 bytes/sec ------- PERIODFACTOR=70: 3571428 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409766 bytes/sec Write: 3126831 bytes/sec ------- PERIODFACTOR=69: 3623188 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409488 bytes/sec Write: 3126814 bytes/sec ------- PERIODFACTOR=68: 3676470 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411062 bytes/sec Write: 3123823 bytes/sec ------- PERIODFACTOR=67: 3731343 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410932 bytes/sec Write: 3126727 bytes/sec ------- PERIODFACTOR=66: 3787878 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410064 bytes/sec Write: 3123747 bytes/sec ------- PERIODFACTOR=65: 3846153 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409485 bytes/sec Write: 3126751 bytes/sec ------- PERIODFACTOR=64: 3906250 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411232 bytes/sec Write: 3126787 bytes/sec ------- PERIODFACTOR=63: 3968253 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410604 bytes/sec Write: 3117937 bytes/sec ------- PERIODFACTOR=62: 4032258 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410059 bytes/sec Write: 3126869 bytes/sec ------- PERIODFACTOR=61: 4098360 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409574 bytes/sec Write: 3124024 bytes/sec ------- PERIODFACTOR=60: 4166666 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410071 bytes/sec Write: 3127021 bytes/sec ------- PERIODFACTOR=59: 4237288 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410932 bytes/sec Write: 3123852 bytes/sec ------- PERIODFACTOR=58: 4310344 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410104 bytes/sec Write: 3123790 bytes/sec ------- PERIODFACTOR=57: 4385964 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409698 bytes/sec Write: 3123845 bytes/sec ------- PERIODFACTOR=56: 4464285 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409365 bytes/sec Write: 3126972 bytes/sec ------- PERIODFACTOR=55: 4545454 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411007 bytes/sec Write: 3123609 bytes/sec ------- PERIODFACTOR=54: 4629629 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2411080 bytes/sec Write: 3120982 bytes/sec ------- PERIODFACTOR=53: 4716981 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409824 bytes/sec Write: 3124089 bytes/sec ------- PERIODFACTOR=52: 4807692 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2409355 bytes/sec Write: 3126760 bytes/sec ------- PERIODFACTOR=51: 4901960 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Async Narrow SCSI Target: FUJITSU MAS3184NC 5205 Read: 2410070 bytes/sec Write: 3124024 bytes/sec ------- PERIODFACTOR=50: 5000000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-5 Narrow SCSI 5.00MB/s period factor 50 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4403514 bytes/sec Write: 4370018 bytes/sec ------- PERIODFACTOR=49: 5102040 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.10MB/s period factor 49 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4948871 bytes/sec Write: 4860589 bytes/sec ------- PERIODFACTOR=48: 5208333 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.20MB/s period factor 48 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4945177 bytes/sec Write: 4856903 bytes/sec ------- PERIODFACTOR=47: 5319148 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.31MB/s period factor 47 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4949661 bytes/sec Write: 4856167 bytes/sec ------- PERIODFACTOR=46: 5434782 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.43MB/s period factor 46 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4948599 bytes/sec Write: 4860232 bytes/sec ------- PERIODFACTOR=45: 5555555 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.55MB/s period factor 45 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4948012 bytes/sec Write: 4860583 bytes/sec ------- PERIODFACTOR=44: 5681818 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.68MB/s period factor 44 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 4943640 bytes/sec Write: 4858534 bytes/sec ------- PERIODFACTOR=43: 5813953 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.81MB/s period factor 43 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5643613 bytes/sec Write: 5463633 bytes/sec ------- PERIODFACTOR=42: 5952380 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 5.95MB/s period factor 42 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5648333 bytes/sec Write: 5468277 bytes/sec ------- PERIODFACTOR=41: 6097560 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.09MB/s period factor 41 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5646045 bytes/sec Write: 5469182 bytes/sec ------- PERIODFACTOR=40: 6250000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.25MB/s period factor 40 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5649371 bytes/sec Write: 5468352 bytes/sec ------- PERIODFACTOR=39: 6410256 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.41MB/s period factor 39 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5641913 bytes/sec Write: 5470912 bytes/sec ------- PERIODFACTOR=38: 6578947 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.57MB/s period factor 38 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 5648858 bytes/sec Write: 5463257 bytes/sec ------- PERIODFACTOR=37: 6756756 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.75MB/s period factor 37 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6577084 bytes/sec Write: 6546182 bytes/sec ------- PERIODFACTOR=36: 6944444 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 6.94MB/s period factor 36 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6574669 bytes/sec Write: 6539720 bytes/sec ------- PERIODFACTOR=35: 7142857 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 7.14MB/s period factor 35 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6574287 bytes/sec Write: 6545521 bytes/sec ------- PERIODFACTOR=34: 7352941 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 7.35MB/s period factor 34 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6578138 bytes/sec Write: 6545712 bytes/sec ------- PERIODFACTOR=33: 7575757 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 7.57MB/s period factor 33 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6577964 bytes/sec Write: 6538883 bytes/sec ------- PERIODFACTOR=32: 7812500 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 7.81MB/s period factor 32 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 6575191 bytes/sec Write: 6545800 bytes/sec ------- PERIODFACTOR=31: 8064516 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 8.06MB/s period factor 31 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7877889 bytes/sec Write: 7713024 bytes/sec ------- PERIODFACTOR=30: 8333333 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 8.33MB/s period factor 30 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7877796 bytes/sec Write: 7719047 bytes/sec ------- PERIODFACTOR=29: 8620689 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 8.62MB/s period factor 29 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7884523 bytes/sec Write: 7719017 bytes/sec ------- PERIODFACTOR=28: 8928571 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 8.92MB/s period factor 28 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7884928 bytes/sec Write: 7718140 bytes/sec ------- PERIODFACTOR=27: 9259259 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 9.25MB/s period factor 27 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7882786 bytes/sec Write: 7712148 bytes/sec ------- PERIODFACTOR=26: 9615384 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 9.61MB/s period factor 26 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 7881515 bytes/sec Write: 7707032 bytes/sec ------- PERIODFACTOR=25: 10000000 bytes/sec -------- Target: FUJITSU MAS3184NC 5205 Negotiated: Fast-10 Narrow SCSI 10.00MB/s period factor 25 offset 15 Target: FUJITSU MAS3184NC 5205 Read: 9811869 bytes/sec Write: 9379597 bytes/sec